2.15 Streamer unit
2.15.1 Checking procedures
1 As there is no specific check procedure for this component, first perform a
check of the indoor unit PCB to check if the streamer unit needs to be
replaced. See "2.8.1Checking procedures"[471].
After complete check of the indoor unit
PCB, is the problem solved?
Action
Yes No further actions required.
No Replace the streamer unit, see
"2.15.2Repair procedures"[4112].
2.15.2 Repair procedures
To remove the streamer unit
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "2.13Plate work"[499].
1 Disconnect the streamer unit connector from the indoor unit PCB.
a
bc
c
a Streamer unit connector
b Streamer unit
c Retainer
2 Route the streamer unit harness out of the retainers.
3 Click the streamer unit out of the indoor unit.
4 To install the streamer unit, see "2.15.2Repair procedures"[4112].