EasyManua.ls Logo

Daikin Stylish Series - Secondary Swing Flap Motor

Daikin Stylish Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 | Components
Service manual
116
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
2.16.2 Secondary swing flap motor
Checking procedures
To perform an electrical check of the swing flap motor
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "2.13Plate work"[499].
1 Disconnect the motor connector from the indoor unit PCB.
2 Measure the resistance between the following pins of the motor connector.
The measurements MUST be as shown in the table below.
Pins Measured resistance (Ω)
1-2 235
1-3
1-4
1-5
2-3 470
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Action
Yes Return to the troubleshooting of the
specific error and continue with the
next procedure.
No Replace the swing flap motor, see
"Repair procedures"[4116].
Repair procedures
INFORMATION
To replace the motor, the complete gearcase assembly MUST be replaced.
To remove the swing flap motor gearcase assembly
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "2.13Plate work"[499].
1 Remove the main swing flap from the indoor unit (by clicking it out).
2 Remove the secondary swing flap from the indoor unit (by clicking it out).
3 Remove the right side fan guard from the indoor unit (by clicking it out).

Table of Contents