a Screw
b Swing flap motor gearcase assembly
3 Disconnect the swing flap motor harness from the swing flap motor.
4 To install the swing flap motor gearcase assembly, see "Repair
procedures"[4114].
To install the swing flap motor gearcase assembly
1 Connect the swing flap motor harness to the swing flap motor connector.
2 Install the swing flap motor gearcase assembly on the indoor unit and tighten
using the 2 screws.
a
ba
a Screw
b Swing flap motor gearcase assembly
3 Install the main swing flap in the indoor unit (by clicking it on).
Is the problem solved? Action