EasyManua.ls Logo

Daikin Sensira Series - Page 95

Daikin Sensira Series
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 | Components
Service manual
95
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
a b
a Nut
b Propeller fan blade assembly
3 Pull and remove the propeller fan blade assembly from the DC fan motor
assembly.
INFORMATION
Use a pulley remover if the propeller cannot be removed manually.
4 To install the propeller fan blade assembly, see "Repair procedures"[494].
To remove the DC fan motor assembly
1 Remove the propeller fan blade assembly from the DC fan motor assembly,
see "Repair procedures"[494].
2 Disconnect the DC fan motor connector from the main PCB.
3 Unlock the ferrite bead.
4 Cut the tie strap.
5 Detach the DC fan motor harness from the switch box.
6 Slightly bend the harness retainers to detach the DC fan motor harness.
7 Remove the 4 screws that fix the DC fan motor assembly.
8 Remove the DC fan motor assembly from the unit.
9 To install the DC fan motor assembly, see "Repair procedures"[494].
To install the DC fan motor assembly
1 Install the DC fan motor assembly in the correct location.
2 Fix the DC fan motor assembly to the unit by tightening the screws.
3 Route the DC fan motor harness through the harness retainers and bend the
harness retainers to attach the DC fan motor harness.
4 Attach the DC fan motor harness to the switch box.
5 Install a new tie strap to fix the DC fan motor harness to the switch box.
6 Connect the DC fan motor connector to the connector on the main PCB.
7 Lock the ferrite bead.
8 Install the propeller fan blade assembly, see "Repair procedures"[494].
To install the propeller fan blade assembly
1 Install the propeller fan blade assembly on the DC fan motor assembly.

Table of Contents