Functions SiBE18-821_C
2 List of Functions
1. Functions
Category Functions
RMXS112/140/160E8V1B
Category Functions
RMXS112/140/160E8V1B
Basic
Function
Inverter (with Inverter Power Control)
{
Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°CDB)
5
~46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
15
~15.5
Air-Purifying Filter with Photocatalytic
Deodorizing Function
PAM Control
Titanium Apatite Photocatalytic
Air-Purifying Filter
Standby Electricity Saving
Compressor Oval Scroll Compressor
{
Air Filter (Prefilter)
Swing Compressor Wipe-Clean Flat Panel
Rotary Compressor Washable Grille
Reluctance DC Motor
{
MOLD PROOF Operation
Comfortable
Airflow
Power-Airflow Flap Good-Sleep Cooling Operation
Power-Airflow Dual Flaps Timer WEEKLY TIMER Operation
Power-Airflow Diffuser 24-Hour ON/OFF TIMER
Wide-Angle Louvers NIGHT SET Mode
Vertical Auto-Swing (Up and Down) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
Horizontal Auto-Swing (Right and Left) Self-Diagnosis (Digital, LED) Display
{
3-D Airflow Wiring Error Check Function
{
COMFORT AIRFLOW Operation Automatic Test Operation
{
Comfort
Control
Auto Fan Speed Memory Function
{
Indoor Unit Quiet Operation
Anti-Corrosion Treatment of Outdoor Heat
Exchanger
{
NIGHT QUIET Mode (Automatic)
{
Flexibility Multi-Split / Split Type Compatible Indoor Unit
OUTDOOR UNIT QUIET Operation (Manual)
{
H/P, C/O Compatible Indoor Unit
2-Area INTELLIGENT EYE Operation Flexible Power Supply Correspondence
INTELLIGENT EYE Operation High Ceiling Application
Quick Warming Function
(Preheating Operation)
{
Chargeless
Hot-Start Function Either Side Drain (Right or Left)
Automatic Defrosting
{
Power Selection
Operation Automatic Operation Remote
Control
5-Room Centralized Controller (Option)
Program Dry Operation
Fan Only
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
Inverter POWERFUL Operation
Remote Control Adaptor
(Normal Open Contact) (Option)
Priority-Room Setting
COOL / HEAT Mode Lock
{
DIII-NET Compatible (Adaptor) (Option)
HOME LEAVE Operation Remote
Controller
Wireless
ECONO Operation Wired
Indoor Unit ON/OFF Button
Signal Receiving Sign
R/C with Back Light
Temperature Display
Note:
{