SiBE18-821_C Test Operation
Test Operation and Field Settings 133
ARC452 Series
(1) Press the ON/OFF button to turn on the system.
(2) Press the both of TEMP buttons and the MODE button at the same time.
(3) Press the MODE button twice.
(“
T
” appears on the display to indicate that trial operation is selected.)
(4) Press the MODE button and select operation mode.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a
trial operation, press the ON/OFF button.
ARC433 Series
(1) Press the ON/OFF button to turn on the system.
(2) Press the center of the TEMP button and the MODE button at the same time.
(3) Press the MODE button twice.
(“
T
” appears on the display to indicate that trial operation is selected.)
(4) Press the MODE button and select operation mode.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a
trial operation, press the ON/OFF button.
(R9675)
(2)
(2) (3) (4)
(1) (5)
(2)
(3)
(2)
(1) (5)
(3)
(2) (3) (4)
(R9663)