SiBE18-821_C RA Indoor Unit
Operation Manual 179
17
INTELLIGENT EYE Operation
NOTE
îš„ Notes on INTELLIGENT EYE operation
• Application range is as follows.
90Ëš
55Ëš
7m
55Ëš
Vertical angle 90Ëš
(Side view)
Horizontal angle 110Ëš
(Top view)
7m
Page 21
CAUTION
[Example]
When somebody in the room
îš„ Normal operation
When nobody in the room Somebody back in the room
îš„
Back to normal operation.
INTELLIGENT EYE operation is useful for energy saving
îš„ Energy saving operation
• The air conditioner is in normal
operation while the sensor is
detecting the movement of people.
• The air conditioner will return to
normal operation when the sensor
detects the movement of people
again.
îš„
20 minutes after, start
energy saving operation.
• The set temperature is shifted in
±2˚C steps.
• If no presence detected in the room for 20 minutes, the energy saving operation will start.
• This operation changes the temperature –2˚C in HEAT / +2˚C in COOL / +1˚C in DRY operation from set temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
• Sensor may not detect moving objects further than 7m away. (Check the application range.)
• Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
• The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
• INTELLIGENT EYE operation will not go on during POWERFUL operation.
• NIGHT SET mode will not go on during use of INTELLIGENT EYE operation.
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus E-Series FFQ50B8V1B and is the answer not in the manual?

Daikin Super Multi Plus E-Series FFQ50B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus E-Series FFQ50B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals