SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series SiBE18-821_C
284 Operation Manual
English 27
Set temp mode changeover
Limit Operation
Operation Method
The limit operation can not be enabled when a centralized control is connected.
1
Basic screen
2
3
Display the main menu screen.
(See page 26.)
Press buttons to select “Set
temp mode changeover” on the
main menu screen.
Pressing Menu/Enter button takes
you back to the basic screen, and
the set temperature is displayed in
max °C min °C.
(Limit Operation)
* To return to the normal set temperature
screen, use “Set temp mode changeover”
in the Main Menu again.
To change the set temperature,
press buttons.
The set temperature is highlighted
and ready to be changed.
The set temperature will increase by
1°C when the button is pressed
and decrease by 1°C when the
button is pressed.
Note
The difference between the maximum and minimum
temperatures cannot be set to less than 6°C.
(* Maximum temperature – Minimum temperature 6°C)
Pressing buttons switches the
variable set temperature between
max. and min.
Limit operation provides thermostat control within the range of the set minimum and maximum temperature.
The minimum temperature setting will trigger heating. The maximum temperature setting will trigger cooling.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus E-Series FFQ50B8V1B and is the answer not in the manual?

Daikin Super Multi Plus E-Series FFQ50B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus E-Series FFQ50B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals