❍ TOTAL ARM AND OFF CHANNELS
❍ ARM RELAY 1 (or 2) AND OFF RELAY 1 (or 2): only possible with a programmable remote control or with the D14411 communicator
(distant command function)
Active channel
Total arm or Off
Total arm or Off
(indicates the state
of the system)
Off and Total arm
Momentary
Arm/Off mode
Arm/Off mode
Activation of the relay for 2 secs. If the relay is already active,
the confirmation of the Off or the Total arm (retransmitted by the
control panel) is done by a deactivation of the relay for 2 secs
Activation of the relay upon receipt of the Total arm channel
(Complete arm or System arm), deactivation upon receipt
of the Off channel (retransmission by the control panel)*
Activation of the relay with the Total arm key of a remote
control and deactivation with the Off key (or with a distant
command)
Operating modes Functionality
Position
of micro-switches
Active channel
Arm relay 1
and Off relay 1
Arm relay 2
and Off relay 2
Arm/Off mode
Arm/Off mode
Activation of the relay upon receipt of Arm Relay 1 channel,
deactivation upon receipt of the Off Relay 1 channel
Activation of the relay upon receipt of Arm Relay 2 channel,
deactivation upon receipt of the Off Relay 2 channel
Operating modes Functionality
Position
of micro-switches
* In this mode if the mains power is cut for more than 2 mins 30 secs, at the time the mains reappears the relay changes its state so mes-
sages of Total arm or Off are not received.