GB
In addition to the protection provided by the control panel with built-in siren and keypad, the
indoor siren
deters intruders
. If a fire is detected, the siren is triggered for 5 minutes in fire
sounding mode.
Thanks to its built-in transmitter, the siren informs the control panel when it has a battery
problem. If somebody attempts to pull the siren off the wall, it sounds and then triggers all
the alerts and deterrents via the control panel.
Vocal messages
The siren issues the following vocal messages:
1. Présentation
IMPORTANT
• Some functions are only available with versions 2.0.0 or later
(press on the control panel keypad to check the version).
• The operating differences with former ranges are described in the compatibility booklet
available in the Daitem installers section at www.daitem.co.uk.
Following
a command
Vocal message
Commands Disarm “bip, Off”
Arm “bip, Armed”
Armed Partial 1 or 2 “bip, Armed Partial 1” or “bip, Armed Partial 2”
Disarm Group “bip, Off”: if all the groups allocated to the siren are disarmed
“bip, Off Group X”: if only part of the groups allocated to the siren
are disarmed
Arm Group “bip, Armed”: if all the groups allocated to the siren are armed
“bip, Armed Group X”: if only part of the groups allocated to the
siren are armed
Arm Presence mode “bip, Armed Presence”
Door bell “ding, dong”
Disarm under duress “bip, Off”
System
status query
Disarm “bip, Off”
Arm “bip, Armed”
Armed Partial 1 or 2 “bip, Armed Partial 1” or “bip, Armed Partial 2”
Disarm group “bip, Off Group X”
Arm Presence mode “bip, Armed Presence”
Alarms Intrusion when
presence mode armed
“bip, bip, bip, bip, intrusion Group X”
Entry delay “bip, bip, bip, bip, Protection Active”
Fire alarm loud sounding for 15 s then “Fire_Alarm” (alternating)
Changing
siren modes
User test mode “bip, TEST_MODE”
Installation mode “bip, INSTALLATION_MODE”
User mode “bip, USER_MODE”