VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
MG.90.D1.02 – VLT is a registered Danfoss trademark
41
Parameter list VLT 5000 Flux
PNU Parameter Factory setting Range Changes Conversion
# description during Index
operation
300 Terminal 16, input Reset Yes Yes
301 Terminal 17, input Freeze reference Yes Yes
302 Terminal 18 Start, input Start Yes Yes
303 Terminal 19, input Reversing Yes Yes
304 Terminal 27, input Coasting stop, inverse Yes Yes
305 Terminal 29, input Jog Yes Yes
306 Terminal 32, input Choice of setup, msb/speed up Yes Yes
307 Terminal 33, input Choice of setup, lsb/speed down Yes Yes
308 Terminal 53, analog input voltage Reference Yes Yes
309 Terminal 53, min. scaling 0.0 V 0.0 - 10.0 V Yes Yes
310 Terminal 53, max. scaling 10.0 V 0.0 - 10.0 V Yes Yes
311 Terminal 54, analog input voltage No operation Yes Yes
312 Terminal 54, min. scaling 0.0 V 0.0 - 10.0 V Yes Yes
313 Terminal 54, max. scaling 10.0 V 0.0 - 10.0 V Yes Yes
314 Terminal 60, analog input current Reference Yes Yes
315 Terminal 60, min. scaling 0.0 mA 0.0 - 20.0 mA Yes Yes
316 Terminal 60, max. scaling 20.0 mA 0.0 - 20.0 mA Yes Yes
317 Time out 10 sec. 1 - 99 sec. Yes Yes
318 Function after time out Off Yes Yes
319 Terminal 42, output 0 - I
MAX
Þ 0-20 mA Yes Yes
321 Terminal 45, output 0 - f
MAX
Þ 0-20 mA Yes Yes
323 Relay 01, output No operation Yes Yes
324 Relay 01, ON delay 0.00 sec. 0.00 - 600 sec. Yes Yes
325 Relay 01, OFF delay 0.00 sec. 0.00 - 600 sec. Yes Yes
326 Relay 04, output No operation Yes Yes
327 Pulse reference, max. frequency 100-65000 Hz 5000 Hz Yes Yes
329 Encoder feedback pulse/rev. 1024 pulses/rev. 1 - 4096 pulses/rev. Yes Yes
341 Terminal 46, digital output No operation Yes Yes
342 Terminal 46, output, pulse scaling 5000 Hz 1-50000 Hz Yes Yes
345 Encoder loss timeout 0 sec. 0 - 60 sec No Yes
350 Encoder monitoring OFF No No 0 5
351 Encoder direction Normal No Yes 0 5
355 Terminal 26, digital output No operation Yes Yes 0 5
356 Terminal 26, output, pulse scaling 5000 Hz 1-50000 Hz Yes Yes 0 6
357 Terminal 42, Output min. scaling 0% 000-100% Yes Yes 0 6
358 Terminal 42, Output max. scaling 100 % 000-500% Yes Yes 0 6
359 Terminal 45, Output min. scaling 0% 000-100% Yes Yes 0 6
360 Terminal 45, Output max. scaling 100% 000-500% Yes Yes 0 6
0
0
0
0
0
0
0
0
0
-1
-1
0
-1
-1
0
-4
-4
0
0
0
0
0
-2
-2
0
0
0
0
0
0
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
5
6
6
5
6
6
4-Setup
Data
type
Parameter list