4 Select Away Mode
Press “M” to enter away mode and
will be displayed.
Press ”<” or ”>”. “SET” appears; set the away mode setpoint.
Press “M” again to exit away mode.
5 Set Timer
For WT-P and WT-PR variants only
Press
; “hh” flashes. Press”<” or ”>” to adjust hour. Press
again; ”mm” flashes. Press ”<” or ”>” to adjust minute. Press
again; “week” flashes. Press ”<” or ”>” to adjust week.
Complete all adjustments. Press any other button to exit (au-
tomatic exit after 6 seconds with no operation).
6 Advanced Programmable Timer
For WT-P and WT-PR variants only
The Advanced Programmable Timer mode enables the setting of a
timer-controlled program for automatic comfort temperature, and
an energy-saving lower setback temperature if standard room
comfort temperature is not required.
The function consists of 2 programs:
Program 1: 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)
Program 2: 4 events in 2 days (Sat. Sun.)
Program 1: Press
to display Mo. Tu. We. Th. Fr.
Program 1, Event 1:
Use ”<” or”>” to select the required start time.
Press
to accept setting.
Use ”<” or ”>” to select the required temperature.
Press
to accept setting.
Program 1, Event 2-4:
Repeat the Event 1 procedure for programming Event
2-4.
Program 2: Sa. Su. are now shown in the display.
Program 2, Event 1:
Use ”<” or ”>” to select the required start time.
Press
to accept setting.
Use ”<” or ”>” to select the required temperature.
Press
to accept setting.
Program 2, Event 2-4:
Repeat the Event 1 procedure for programming Event
2-4.
The thermostat will continue the 4-event program based on
the present time and day.
To set and change the desired room temperature temporari-
ly:
Press “<” or ”>” at any time to change the desired tem-
perature value. "SET" is shown in the display.
When releasing the “<” or ”>”, the display returns to
showing the actual temperature. This temperature
change is only temporary and will be maintained only
until the next programmed setting!
A default program provides timer control if the customer
does not set own programs. The default program is as fol-
lows.
Weekday/
Weekend
Event 1 Event 2 Event 3 Event 4
Start time/temp.
Weekday,
Mon-Fri.
6:30/20 °C 8:30/15 °C 16:30/20 °C 22:30/15 °C
(27 °C)* (25 °C)* (27 °C)* (25 °C)*
Weekend,
Sat. -Sun.
7:30/20 °C 9:30/20 °C 16:30/21 °C 22:30/15 °C
(27 °C)* (27 °C)* (28 °C)* (25 °C)*
* Floor temperature control mode.
7 Check Floor Temperature
Press “M” and hold. Press “<” within 6 seconds.
flashes and the current floor temperature is displayed. Operate
again, then exit (automatic exit after 6 seconds with no operation).
User Guide
Basic Plus
2
Room Thermostats Floor Heating
VUCUA102 Danfoss Heating Solutions
4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Basic Plus2 and is the answer not in the manual?

Danfoss Basic Plus2 Specifications

General IconGeneral
BrandDanfoss
ModelBasic Plus2
CategoryThermostat
LanguageEnglish

Related product manuals