TP5000 Si Range
Installation and User Instructions
Electronic 5/2 day programmable room thermostat
Mains, Battery and RF versions
GB
®
Certification Mark
Question and Answer IconNeed help?

Do you have a question about the Danfoss TP5000 si range and is the answer not in the manual?

Danfoss TP5000 si range Specifications

General IconGeneral
DisplayLCD
Temperature Range5°C to 30°C
Switching Voltage230V AC
Frost ProtectionYes
Accuracy±0.5°C
Protection ClassIP30
TypeRoom thermostat
ProgrammingProgrammable
Power SupplyBattery
Battery Type2x AA
MountingWall Mount
Ambient Temperature0°C to 40°C
Switching Current5A (resistive)

Summary

TP5000 Si Range

Electronic 5/2 day programmable room thermostat

Describes the product as a 5/2 day programmable room thermostat for electronic control.

GB Installation and User Instructions

Indicates the document provides installation and user guidance for the thermostat.

Installation Instructions

Product Specification

Provides detailed technical specifications for the TP5000 Si range of thermostats.

Installation

Thermostat and Remote Room Sensor

Guidance on the correct placement and mounting of the thermostat and its remote sensor.

Cable Access

Wiring

Details the electrical wiring connections for different models of the thermostat.

Models with remote sensor inputs

RX Receiver Wiring (RF models only)

Commissioning (RF models only)

Steps required to commission RF models, including pairing with receiver units.

Installer advanced programming options

Installer advanced programming options

Details advanced features configurable by installers to optimize system performance.

Service Interval Timer

Entering Installer Advanced Programming Mode

Step-by-step guide on how to access the advanced installer programming menu.

Option 30 - Set upper limit of temperature range

Configuration option to electronically limit the thermostat's upper temperature setting.

Option 31 - Set lower limit of temperature range

Configuration option to electronically limit the thermostat's lower temperature setting.

Installer Advanced Programming Options (Continued)

Option 41 - Operating Mode (5/2 day or 24 hour)

Sets the thermostat to operate in either 5/2 day or 24 hour mode.

Option 34 - Select On/Off or Chrono-proportional

Sets the thermostat's operating mode to On/Off or Chrono-proportional.

Option 90 - Define remote sensor type

Allows the type of remote sensor input to be defined for 'A' models.

Option 93 - Set limit sensor set-point

Sets the limit sensor set-point for 'A' models, typically for floor heating.

User Instructions

Setting the correct date and time

Changing the preset programmes

Changing the preset programmes (Continued)

Changing preset programmes for AB programming

User Overrides

Remote override into and out of thermostat mode

Delay start feature

Optimum start control (OSC)

User Advanced Programming Options

To access User Advanced Programming

Guide on how to enter the User Advanced Programming mode.

User Advanced Programming Options (Continued)

Option 12 - Optimum start control pre-heat setting

Sets the pre-heat period for Optimum Start Control to match building energy characteristics.

Option 11 - Start-up method

Configures how the thermostat starts up the system (Normal, OSC, or Delay Start).

Overview of installer selectable features

What happens to the unit when batteries fail

Describes unit behavior and installer options during battery failure.

Resetting the unit

Settings Reference