Installation Instructions
GB
Installation
First, remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 15mm to the right, 15mm to the left, 30mm
above and 100mm below in order to mount the plug-in module.
Thermostat and Remote Room Sensor:
Fix at a height of approximately 1.5m from the  oor, away from
draughts or heat sources such as radiators, open  res or direct
sunlight.
Prior to mounting the unit the 2 DIL switches on the rear of the
unit have to be moved to the required position. The factory
presets are shown below.
1
2
Keyboard disabled
Reset disabled Reset enabled
Keyboard enabled
OFF
ON
Sw. No.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss TP5000 si range and is the answer not in the manual?

Danfoss TP5000 si range Specifications

General IconGeneral
DisplayLCD
Temperature Range5°C to 30°C
Switching Voltage230V AC
Frost ProtectionYes
Accuracy±0.5°C
Protection ClassIP30
TypeRoom thermostat
ProgrammingProgrammable
Power SupplyBattery
Battery Type2x AA
MountingWall Mount
Ambient Temperature0°C to 40°C
Switching Current5A (resistive)