8 VI.UH.R2.1C Produced by Danfoss Floor Heating Hydronics 03.2007
Instruction CF-RF Room Thermostat with Infrared Floor Sensor
Floor surface temperature limitation
1. Ensure actual oor surface temperature is
shown in the display illustrated by
2. Press and hold the push button until SET
MAX is also shown in the display
3. Press the up/down selector to set the
maximum oor surface temperature limitation
4. Press the push button shortly, SET MIN is
also shown in the display
5. Press the up/down selector to set the mini-
mum oor surface temperature limitation
IMPORTANT!
As heat emission from the oor may vary slightly
depending on oor covering - and thereby cause
inaccurate temperature measurement - it may be
necessary to adjust the setting of max. and min.
oor surface temperatures accordingly.
! It is important always to follow recommendations
from the oor manufacturer regarding max. oor
surface temperature.
! It is recommended always to include mixing shunt
for oor heating circuits in order to ensure optimal
ow temperature. - In addition to minimised energy
consumption, correct setting of the ow tempera-
ture will eliminate the risk of excessive heat transfer
to the oor.