9. Glossary
RCD
Residual Current Device.
An electronic device normally located in the electric supply branch of a building.
It monitors the dierence between in-going and outgoing current and if this
dierence exceeds a threshold, say 30mA, it will cut o the mains supply.
HVU High Voltage Unit, also known as the burner.
Burner The HVU of the DEVItector™ II V2 equipment.
Tracer
An electromagnetical sensor which transform a magnetic ux into an acoustic
signal. The amplitude indicates the proximity to the heating cable.
Connection coupling
The electric connection between the conductive (cold) and resistive (warm) parts
of a complete heating cable.
Screen
Electrical shielding surrounding the live parts of the heating cable. The screen may
be realized as twisted wires or a wrapped foil.
Conductor Common term for either a heating wire or the screen
10. Ordering information
For safety reasons do only use replacements delivered from Danfoss A/S according to the table below.
Item no. Description EAN no.
12609001 Magnetic tracer on crutch for DEVItector™ II V2 5703465026602
12609002
DEVItector™ II V2 High Voltage Unit (Burner) with Magnetic tracer - Hand held
5703466111352