EasyManua.ls Logo

Danfoss iC7 Series

Danfoss iC7 Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
Functions
Data
Maximum terminal load (DC-13) : Inductive load
24 V DC, 0.1 A
Minimum load
24 V DC, 10 mA
24 V AC, 20 mA
Rated number of cycles (@2 A resistive load)
400 000 switchings
Cable type
Cu, 75 °C (167 °F)
Cable size
Solid: 0.2–2.5 mm
2
(24–14 AWG)
Flexible: 0.2–2.5 mm
2
(24–14 AWG)
Flexible with ferrule, without plastic sleeve: 0.25–2.5 mm
2
(24–14 AWG)
Flexible without ferrule, with plastic sleeve: 0.25–2.5 mm
2
(24–14 AWG)
Maximum cable length
300 m (984 ft)
Maximum altitude
4400 m (14400 ft)
N O T I C E
The operating altitude sets requirements on voltages.
For the wiring diagrams for different operating altitudes, see 6.5.1 Wir-
ing Diagrams for Different Operating Altitudes.
Ambient temperature
-30 °C...60 °C (-22 °F...140 °F)
Weight
0.12 kg (0.26 lb)
Environment
Overvoltage category III/pollution degree 2
6.5 Setup and Connection Examples for Relay Option OC7R0
1 2 3 4 5 6 7 8
X101
(T2)
X102
(T5)
X103
(T8)
e30bk032.10
Illustration 25: Wiring Configuration for Relay Option OC7R0
AQ390830267692en-000601 / 136R0273 | 45Danfoss A/S © 2023.06
Relay Option Installation and
Configuration
Functional Extension Options
Operating Guide

Other manuals for Danfoss iC7 Series

Related product manuals