Installation Guide
Danfoss Icon™ Master Controller 24 V

Table of Contents

Questions and Answers

  • S
    Sydney StrongAug 16, 2025
    How to set up a reference room thermostat for Danfoss Icon Controller cooling application?
    • A
      Andrew EwingAug 16, 2025
      To set up a cooling application that needs a reference room thermostat, go to the thermostat in the desired reference room and enter the thermostat installer menu. Set the thermostat to ON in ME.6 'reference room thermostat'.
  • D
    Debra NguyenAug 19, 2025
    What to do if Danfoss Icon communication is lost to room thermostat?
    • V
      vcampbellAug 19, 2025
      If you've lost communication between your Danfoss Icon Controller and a room thermostat, there are a few things you can try. First, identify the affected thermostat by observing the flashing outputs on the Danfoss Icon Master Controller. Alternatively, check the thermostats themselves. Wake up the thermostat and press it. A failing thermostat will display 'NET ERR'. If the problem persists, consider adding a repeater to improve wireless communication. You may also need to replace the batteries in the room thermostat and perform a network test by activating NET TEST in menu ME.3 on the room thermostat.
  • C
    Cynthia HicksAug 22, 2025
    How to fix communication lost to Radio Module on Danfoss Controller?
    • T
      tdouglasAug 22, 2025
      If your Danfoss Controller loses communication with the Radio Module, make sure the cable is correctly connected to both the Radio Module and the Danfoss Icon™ Master Controller 24V.
  • T
    taylorjessicaAug 25, 2025
    What to do if Danfoss Icon communication is lost to Slave Controller?
    • M
      melissariveraAug 26, 2025
      If the Danfoss Controller loses communication with a Slave Controller, check the following: if it is a wireless system, verify the Radio Module connection to the Danfoss Icon™ Master Controller 24V. If it's a wired system, inspect the wire connecting the controllers.
  • D
    Dr. Dana HarrisonAug 28, 2025
    How to troubleshoot communication lost from Slave to Master Controller on Danfoss system?
    • J
      Jennifer BakerAug 28, 2025
      If communication is lost from the Slave to the Master Controller in your Danfoss system, check the Radio Module connection to the Danfoss Icon™ Master Controller 24V if it's a wireless setup. For wired systems, inspect the wire connecting the controllers.
  • E
    Evan Wilson IVAug 31, 2025
    What to do if Danfoss Icon Controller communication is lost to Expansion Module?
    • M
      malikhallAug 31, 2025
      If your Danfoss Controller loses communication with the Expansion Module, ensure that the Expansion Module is fully inserted into its place. Remember to turn the Master Controller off and then on again to register the expansion module.
  • M
    melissa13Sep 3, 2025
    How to fix a defective actuator on Danfoss Icon Controller?
    • B
      Brian WillisSep 3, 2025
      If you have a defective actuator, and the corresponding output is flashing, the solution is to replace the actuator.
  • J
    Jacob MorrisSep 5, 2025
    What to do if Danfoss Icon Controller communication is lost to Repeater?
    • A
      Amy BrownSep 6, 2025
      If communication is lost to the Repeater, verify that the repeater is properly plugged into an outlet, that it has not been removed, and that the outlet is powered ON.
  • R
    Robert LeeSep 9, 2025
    Why does Danfoss Icon say a specific actuator output is unavailable?
    • J
      Jasmine HendersonSep 9, 2025
      If a specific actuator output is required but unavailable, it's because the output has already been assigned to a room thermostat, or an actuator has not yet been fitted. To resolve this, uninstall the RT from TWA, ensuring it is available to the chosen application (or fit the actuator if this hasn't been done).
  • S
    skinneremilySep 12, 2025
    What to do if external PT1000 sensor is not fitted or defective in Danfoss Controller?
    • T
      Tyler ParkerSep 12, 2025
      If the external PT1000 sensor is not fitted or is defective, check the sensor and replace it if necessary. Ensure that the Master Controller is disconnected due to risk of electric shock.

Summary

Installation

Setting Up The System

Step-by-step guide for initial system configuration and thermostat inclusion.

Operation Modes

Removing System Components

Removing a Thermostat

Step-by-step guide to safely remove a thermostat from the Danfoss Icon™ system.

Uninstalling a Defective Thermostat

Process for removing a malfunctioning thermostat to maintain system integrity.

Resetting or Replacing Master Controller

Master Controller Factory Reset

Steps to perform a factory reset on the Master Controller to restore default settings.

Troubleshooting Common Errors

Hydraulic Balance Optimization

Firmware Update Process

Danfoss Icon Series Specifications

General IconGeneral
MountingWall-mounted
Protection ClassIP20
Housing MaterialPlastic
TypeController
DisplayLCD
ConnectivityWireless
CommunicationZigbee
FeaturesAway mode
Storage Temperature-20°C to 60°C