Placement of Danfoss Link™ FT
Installation and placement must be according to local
building regulations.
Operation mode
Danfoss Link™ FT supports two types of operation modes.
1. Heating regulation
2. On/OFF switching
When used in heating regulation mode you have to consider
the following advices for controlling the heating.
When used as simple ON/OFF mode do not connect floor
sensor.
Sensor combination
When installing the Danfoss Link™ FT you need to consider
the type of heating and thus which sensors should be used.
There are three options:
1. Comfort heating: Constant temperature on the floor in
bathrooms and other rooms where a comfortable warm
surface is required. Install the Floor sensor and choose
Floor regulation for the room when doing the configura-
tion.
2. Total heating: Control of room temperature in living
rooms etc. Install the floor sensor and a Danfoss Link™ RS.
Choose Combined regulation when doing the configura-
tion on the Danfoss Link™ CC.
3. No floor sensor: A floor sensor is not present, and cannot
be installed. You must install a Danfoss Link™ RS. Choose
Room regulation.