MCD3000 Series
MG.15.B2.02 VLT is a registered Danfoss trademark 1
Contents
Warnings ...................................................................... 3
Section 1.0
Spare Parts
1.1 Main Control Module .............................................. 4
1.2 Identity Module (Line Connection) ....................... 5
1.3 Identity Module (Inside Delta Connection) .......... 6
1.4 Snubber/Overvoltage Protection Module ........... 7
1.5 SCRs / Power Assemblies .................................... 9
1.6 Cooling Fans .......................................................... 12
1.7 Power Transformers ............................................. 13
Section 2.0 Tests
2.1 Start Performance Test ........................................ 15
2.2 Run Performance Test ......................................... 15
2.3 Power Circuit Test ................................................ 15
2.4 Control Input Test ................................................. 16
2.5 Power Transformer Test ...................................... 16
Section 3.0 Component Replacement Procedures
3.1 Main Control Module
3007~3132 .............................................................. 17
3185~3800 .............................................................. 17
3.2 Identity Module
3007~3132 .............................................................. 18
3185~3800 .............................................................. 18
3.3 Snubber/Overvoltage Protection Module
3007~3055 .............................................................. 19
3075~3132 .............................................................. 19
3185~3500 .............................................................. 20
3600~3800 .............................................................. 22
3.4 SCR / Power Assemblies
3007~3132 .............................................................. 23
3185~3800 .............................................................. 25
3.5 Cooling Fans
3030~3055 .............................................................. 27
3075~3110 .............................................................. 29
3132 .......................................................................... 31
3185~3800 .............................................................. 33
3.6 Power Transformers
3007~3055 .............................................................. 34
3075~3110 .............................................................. 35
3132~ ....................................................................... 36
3185~3800 .............................................................. 37
Section 4.0 Schematics
4.1 3007~3022 T5 ....................................................... 39
4.2 3030~3055 T5 .........................................................40
4.3 3075~3110 T5 .........................................................41
4.4 3132 T5 ....................................................................42
4.5 3185~3500 T5 .........................................................43
4.6 3600~3800 T5 .........................................................44
4.7 3007~3022 T7 ........................................................ 45
Question and Answer IconNeed help?

Do you have a question about the Danfoss MCD3000 Series and is the answer not in the manual?

Danfoss MCD3000 Series Specifications

General IconGeneral
Protection ClassIP20
Frequency50/60 Hz
Rated Control Supply Voltage24 V DC
Communication ProtocolsModbus RTU
Operating Temperature-10°C to +50°C
Ambient TemperatureUp to 50 °C (without derating)
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level
Cooling MethodNatural convection

Summary

Section 1.0 Warnings

Safety, Symbols, and Damage Prevention

Covers safety regulations, unintended starts, symbols, and damage avoidance.

Spare Parts

Lists spare parts for MCD3000 series, including modules, fans, and transformers.

Section 2.0 Tests

Performance and Circuit Tests

Details start, run, power circuit, and transformer tests.

Control Input Test

Verifies the correct operation of remote control inputs.

Section 3.0 Component Replacement Procedures

Module and Protection Component Replacement

Procedures for replacing Control, Identity, and Snubber/Overvoltage modules.

SCRs, Power Assemblies, and Fans

Procedures for replacing SCRs, Power Assemblies, and Cooling Fans.

Power Transformer Replacement

Step-by-step guide to replacing the Power Transformer.

Section 4.0 Schematics

T5 Series Schematics

Wiring schematics for MCD3000 T5 models.

T7 Series Schematics

Wiring schematics for MCD3000 T7 models.

Section 5.0 Appendix

SCR Damage and Relay Compatibility

Discusses SCR damage causes and output relay compatibility.

Remote Control Input Failure

Explains causes and testing for remote control input failures.