MCD3000 Series
MG.15.B2.02 VLT is a registered Danfoss trademark 21
Component Replacement Procedures
Step 7. Unplug the SCR leads.
Step 8. Undo fixing screws (2), undo the fixing nuts (6)
and remove the Snubber/Overvoltage Protection
Module.
Step 9. Fit the new Snubber/Overvoltage Protection
Module in reverse order.