2018
EcoDesign
For more information related to EcoDesign compliance, please refer to Coolselector®
coolselector.danfoss.com or contact Danfoss
Optyma
Plus INVERTER, R407F
Product description
Model number
Code
number
Compressor
Compressor
speed, rps
Tamb [°C]
Cooling capacity Q [kW] P [kW] EcoDesign (2)
Sound power
level dB(A)
Sound pressure
level 10 m dB(A)
Te [°C]
COP
(1)
Q [kW] P [kW] COP
A
SEPR
-15 C -10 C -5 C 0 C 5 C -10°C
OP-MPPM028VVLP01E 114X4302 VLZ028TGA
30
27 1534 1915 2363 2888 3496
71.7 40.7
32 1447 1808 2234 2733 3313 945 1.91
38 - 1679 2078 2547 3092
43 - - - - -
50
27 2598 3258 4022 4900 5902
72.3 41.3
32 2450 3083 3815 4655 5613 1410 2.19
38 - 2862 3555 4349 5254
43 - 2669 3328 4083 4943
75
27 3826 4792 5901 7163 8590
72.9 41.9
32 3612 4539 5600 6806 8169 2121 2.14
38 - 4220 5223 6362 7647
43 - 3942 4895 5977 7197
100
27 4950 6174 7573 9158 10939
74.2 43.2
32 4689 5857 7191 8703 10400 2977 1.97 5905 2979 1.98 3.58
38 - 5470 6724 8145 9742
43 - 5141 6327 7671 9182
OP-MPPM035VVLP01E 114X4316 VLZ035TGA
30
27 1931 2408 2969 3623 4380
71.2 40.2
32 1820 2272 2805 3428 4149 1115 2.04
38 - 2110 2609 3193 3871
43 - - - - -
50
27 3258 4080 5029 6116 7351
71.9 40.9
32 3069 3858 4766 5804 6984 1698 2.27
38 - 3577 4435 5416 6529
43 - 3330 4147 5078 6135
75
27 4776 5970 7334 8878 10612
72.5 41.5
32 4503 5648 6951 8425 10079 2594 2.18
38 - 5242 6472 7860 9417
43 - 4888 6055 7372 8847
100
27 6156 7655 9358 11274 13409
73.55 42.5
32 5825 7254 8876 10699 12731 3679 1.97 7326 3682 1.99 3.71
38 - 6764 8286 9996 11902
43 - 6347 7783 9397 11198
OP-MPPM044VVLP01E 114X4334 VLZ044TGA
30
27 2464 3068 3778 4603 5555
72 41
32 2322 2895 3568 4354 5260 1353 2.14
38 - 2686 3316 4052 4903
43 - - - - -
50
27 4135 5170 6359 7714 9244
72.6 41.6
32 3891 4882 6019 7311 8771 2105 2.32
38 - 4519 5591 6809 8184
43 - 4200 5218 6374 7677
75
27 6024 7510 9195 11089 13196
73.2 42.2
32 5670 7092 8700 10503 12509 3271 2.17
38 - 6567 8080 9774 11658
43 - 6107 7540 9143 10924
100
27 7723 9567 11641 13951 16496
74 43
32 7298 9052 11023 13215 15631 4694 1.93 9164 4701 1.95 3.78
38 - 8421 10265 12315 14574
43 - 7884
9618 11548 13675
SEPR, Seasonal Energy Performance Ratio
Q [W], Cooling Capacity
P [W], Power Input
[1] Nominal conditions, Evaporating temperature -10°C. Ambient air temperature +32°C. Superheat 10K.
[2] Rated conditions, Evaporating temperature -10°C. Ambient air temperature +32°C. Return Gas Temperature 20°C