EasyManuals Logo

Danfoss PLUS+1 MC024-110 User Manual

Danfoss PLUS+1 MC024-110
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Specifications (continued)
Description Units Minimum Maximum Comment
Absolute accuracy of full range % of full scale 3 1% typical. Offsets removed
when command is Ø.
Output settling time ms 100 Depends on load
characteristics.
PWM frequency Hz 33 4000 Some pins have a fixed
frequency, consult module
application program interface
(API).
Dither frequency Hz 33 250 Increased in steps, see module
API.
Dither amplitude A 0 0.5 Increased in steps, see module
API.
Over-current trip point A 5 5.25 There is over-current protection
built into each output driver. If
the instantaneous current
exceeds the trip point, the
driver is latched off. GUIDE
application software can reset
the latch and attempt to drive
current again.
Technical Information
PLUS+1® MC0XX-1XX Controller Family
Inputs/outputs types and specifications
©
Danfoss | April 2018 L1321895 | BC00000227en-US0401 | 17