Danfoss VLT 5000 Crane Series - Serial Communication; Factory Settings

Danfoss VLT 5000 Crane Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL 5000 Crane
Serial
communication
PNU Parameter Range Factory Changes Unit Conversion Data Protection
#description
Serial communication
setting during
operation
index index type level
500 Address 1 - 126 1 Yes 0 0 6 1
501 Baudrate 300 - 19200
Baud
9600 Baud Yes 0 0 5 1
503 Quick-stop Logic or Yes 0 0 5 1
505 Start Logic or Yes 0 0 5 1
506 Reversing Digital input Yes 0 0 5 1
512 Drive profile Crane profile No 0 0 5 1
515 Data read-out: Reference % No 24 -1 3 2
516 Data read-out: Reference unit No -1 -3 4 2
517 Data read-out: Feedback No -1 -3 4 2
518 Data read-out: Frequency No 28 -1 6 2
519 Data read-out: Motor speed No 11 67 3 2
520 Data read-out: Current No 22 -2 7 2
521 Data read-out: Torque No 24 -1 3 2
522 Data read-out: Power, kW No 9 1 7 2
523 Data read-out: Power, HP No 9 -2 7 2
524 Data read-out: Motor voltage No 21 -1 6 2
525 Data read-out: DC link voltage No 21 0 6 2
526 Data read-out: Motor thermal No 24 0 5 2
527 Data read-out: VLT thermal No 24 0 5 2
528 Data read-out: Digital input No 0 0 5 2
529 Data read-out: Term. 53,
analogue input
No 21 -2 3 2
530 Data read-out: Term. 58,
analogue input
No 21 -2 3 2
531 Data read-out: Term. 60,
analogue input
No 22 -5 3 2
533 Data read-out: External
reference %
No 24 -1 3 2
534 Data read-out: Status word,
binary
No 0 0 6 2
535 Data read-out: Brake energy/2
min.
No 9 2 6 2
536 Data read-out: Brake
energy/sec.
No 9 2 6 2
537 Data read-out: Heat sink
temperature
No 17 0 5 2
538 Data read-out: Alarm word,
binary
No 0 0 7 2
539 Data read-out: VLT control
word, binary
No 0 0 6 2
540 Data read-out: Warning word No 0 0 7 2
541 Data read-out: Warning word,
2
No 0 0 7 2
580 Defined parameters 1 No 0 0 6 2
581 Defined parameters 2 No 0 0 6 2
582 Defined parameters 3 No 0 0 6 2
For information on conversion index and data type,
please refer to Factory Setting in Programming .
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
81