EasyManuals Logo

Danfoss VLT 8022 AQUA User Manual

Danfoss VLT 8022 AQUA
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
VLT
®
8000 AQUA
Externals:
Enclosure .................................................................................. IP00/Chassis, IP20/IP21/NEMA 1, IP54/NEMA 12
Vibration test .................................. 0.7 g RMS 18-1000 Hz random. 3 directions for 2 hours (IEC 68-2-34/35/36)
Max. relative humidity ............................................................. 93 % +2 %, -3 % (IEC 68-2-3) for storage/transport
Max. relative humidity ................................................ 95% non condensing (IEC 721-3-3; class 3K3) for operation
Aggressive environment (IEC 721-3-3) .................................................................................... Uncoated class 3C2
Aggressive environment (IEC 721-3-3) ........................................................................................ Coated class 3C3
Ambient temperature, VLT 8006-8011 380-480 V,
8002-8011 525-600 V, IP 20//NEMA 1 .......................... Max. 45°C (117°F) (24-hour average max. 40°C (104°F))
Ambient temperature IP00/Chassis, IP20/NEMA 1, IP54/NEMA 12 ................................................................ Max.
40°C/104°F (24-hour average max. 35°C/95°F)
see Derating for high ambient temperature
Min. ambient temperature in full operation ............................................................................................. 0°C (32°F)
Min. ambient temperature at reduced performance ........................................................................... -10°C (14°F)
Temperature during storage/transport ......................................................... -25° - +65°/70°C (-13° - +149°/158°F)
Max. altitude above sea level ........................................................................................................ 1000 m (3300 ft)
see Derating for high air pressure.
IP54 units are not intended for direct outdoor installation. The IP54 rating does not relate to other
exposures as sun, icing, wind blown driving rain. Under such circumstances Danfoss recommends to
install the units in an enclosure designed for these environmental conditions. Alternatively, an installation
at minimum 0.5 m above surface and covered by a shed is recommended.
NB!:
VLT 8002-8072, 525-600 V units do not comply
with EMC, Low Voltage or PELV directives.
MG.83.A2.02 - VLT is a registered Danfoss trademark
34