  • F
    fphillipsSep 12, 2025
    What does 'Broken Belt' mean on Danfoss VLT CDS 803?
    • J
      jessicasuarezSep 12, 2025
      The 'Broken Belt' message on Danfoss DC Drives means the torque is below the torque level set for no load, indicating a broken belt. See parameter group 22-6* Broken Belt Detection.
  • D
    Danielle SantiagoAug 25, 2025
    What does 'Inverter over-load' mean on Danfoss VLT CDS 803 DC Drives?
    • H
      heather14Aug 25, 2025
      An 'Inverter over-load' message on Danfoss DC Drives means the drive has experienced more than 100% load for an extended period.
  • T
    Terry LambAug 25, 2025
    What does 'Earth Fault' mean on Danfoss DC Drives?
    • M
      Mason RiggsAug 26, 2025
      An 'Earth Fault' on Danfoss DC Drives suggests a discharge from output phases to ground.
  • M
    mary41Sep 23, 2025
    What does Ctrl. word TO mean in Danfoss DC Drives?
    • M
      Mary BlackSep 23, 2025
      This indicates a loss of communication to the frequency converter. See parameter group 8-0* General Settings for troubleshooting.
  • L
    lisa61Sep 12, 2025
    What does 'Locked rotor' mean on Danfoss VLT CDS 803 DC Drives?
    • C
      Chase SloanSep 12, 2025
      The 'Locked rotor' message on Danfoss DC Drives means the rotor is locked or the load is too high.
  • M
    Melissa MillsSep 16, 2025
    What does 'AMA big motor' mean on Danfoss DC Drives?
    • M
      Michael EvansSep 16, 2025
      The message 'AMA big motor' on Danfoss DC Drives indicates that the motor is too big to perform AMA.
  • O
    Olivia BarnesSep 5, 2025
    What does 'Current limit' mean on Danfoss VLT CDS 803?
    • C
      Christopher HunterSep 5, 2025
      If your Danfoss DC Drives display the message 'Current limit', it means the current is higher than the value set in parameter 4-18 Current Limit.
  • D
    Deanna BoyerSep 5, 2025
    How to fix 'Live zero error' on Danfoss VLT CDS 803 DC Drives?
    • A
      Ashley AcostaSep 5, 2025
      A 'Live zero error' occurs when the signal on terminal 53 or 54 is less than 50% of the value set in parameter 6-10 Terminal 53 Low Voltage, parameter 6-12 Terminal 53 Low Current, parameter 6-20 Terminal 54 Low Voltage, or parameter 6-22 Terminal 54 Low Current. See also parameter group 6-0* Analog I/O Mode.
  • D
    David MyersSep 17, 2025
    What does 'AMA small mot' mean on Danfoss DC Drives?
    • T
      Timothy JohnsonSep 17, 2025
      The message 'AMA small mot' on Danfoss DC Drives indicates that the motor is too small to perform AMA.
  • L
    lhensleyAug 30, 2025
    What does 'Illegal FC configuration' mean on Danfoss VLT CDS 803 DC Drives?
    • J
      John GoodAug 30, 2025
      The message 'Illegal FC configuration' on Danfoss DC Drives indicates that the control card and power card are not matched.

Summary

Introduction to VLT Compressor Drive CDS 803

Purpose and Resources

Details guide purpose, supplementary documentation, and software support.

Manual Version and Approvals

Lists manual/software versions and product approvals/certifications.

Safety Guidelines for VLT Compressor Drive CDS 803

Safety Symbols and Personnel

Explains safety symbols and requirements for qualified personnel.

Critical Safety Precautions

Details essential safety measures for hazardous voltage and unintended starts.

Specific Hazards and Warnings

Highlights hazards like discharge time, leakage, equipment contact, and internal failures.

Product Overview of VLT Compressor Drive CDS 803

CDS 803 Family Overview

Introduces the CDS 803 family, listing common I/Os and communication features.

Key Compressor Features

Details specialized functions for compressor systems like Secure Start-up and speed detection.

Application Features

Details custom application functions like AMA, PID control, and Smart Logic Control.

Drive Protections

Details built-in protection functions for mains input, output, temperature, and internal faults.

Ecodesign for Power Drive Systems

Explains the Ecodesign Directive for energy-related products in Europe.

Specifications for VLT Compressor Drive CDS 803

Electrical Data

Presents detailed electrical specs for 3x200-240V and 3x380-480V AC systems.

Mains Supply and Output Specs

Details mains supply parameters and compressor output voltage.

Control Input;Output Details

Lists specifications for all control inputs, outputs, relays, and communication.

Ambient Conditions and Standards

Specifies ambient conditions, environmental requirements, and conforming standards.

Cable Specs, Noise, and Dimensions

Details cable lengths, acoustic noise sources, and mechanical dimensions.

dU;dt Data

Presents dU/dt data including cable length, voltage, and rise time.

Mechanical Installation Considerations

Transportation, Storage, and Capacitors

Provides guidelines for safe handling, storage, and capacitor reforming.

Installation Environment

Details side-by-side clearance, operating environment, gases, dust, and humidity.

Derating for Temperature and Altitude

Explains derating due to ambient temperature, switching frequency, and high altitudes.

Derating Curves

Presents derating curves for various power ratings based on temperature and frequency.

IP21;NEMA Type 1 Enclosure Kit

Describes the optional IP21/NEMA Type 1 enclosure kit for enhanced protection.

Electrical Installation Considerations

General Installation and Protection

Covers general installation, cable specs, and fuse/breaker recommendations.

Wiring and Terminals

Details wiring schematics, terminal layouts, and connection procedures.

IT Grid Installations and Relays

Guides IT grid installations and details relay terminal configurations.

RS485 Communication Setup

Guides on configuring RS485 serial communication for drives.

Electromagnetic Compatibility (EMC)

Discusses EMC, interference sources, requirements, and compliant installation.

EMC-compliant Installation and Cables

Provides instructions for EMC-compliant installation and cable selection.

RFI Filters and Harmonics

Explains RFI filter usage and discusses harmonics emission.

Galvanic Isolation and Leakage Current

Details galvanic isolation, PELV requirements, and ground leakage current.

Residual Current Device (RCD) Usage

Provides guidelines for using RCDs for leakage current protection.

How to Order VLT Compressor Drive CDS 803

Drive Configurator and Type Code

Guides to the online configurator and explains the type code structure for ordering.

Accessories and Spare Parts

Lists available accessories and spare parts with their respective order numbers.

Appendix

Abbreviations Glossary

Provides a comprehensive glossary of abbreviations used in the manual.

Document Conventions

Explains conventions used for lists, bold, and italic text in the document.

Danfoss VLT CDS 803 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CDS 803
CategoryDC Drives
LanguageEnglish

Related product manuals