Questions and Answers

  • R
    riceedwardAug 30, 2025
    What causes line power current imbalance greater than 3% in Danfoss DC Drives?
    • M
      Matthew WilsonAug 30, 2025
      If you notice a line power current imbalance greater than 3% in your Danfoss DC Drives, it could be a problem with the line power supply itself. Check the line power supply. If the imbalance remains on the same input terminal, there may be a problem with the unit, and you should contact the supplier.
  • S
    Sharon YoungAug 25, 2025
    What does parameter error mean on Danfoss DC Drives?
    • M
      meganthomasAug 25, 2025
      If your Danfoss DC Drives displays a parameter error, it means the parameter is out of range.
  • M
    michael32Sep 23, 2025
    What causes 10 Volts low error in Danfoss DC Drives?
    • K
      Kristina McfarlandSep 23, 2025
      A '10 Volts low' error in Danfoss DC Drives can be caused by a short in a connected potentiometer or improper wiring of the potentiometer. Remove the wiring from terminal 50. If the warning clears, the problem is with the customer wiring. If the warning does not clear, replace the control card.
  • L
    Lauren DurhamSep 3, 2025
    What to do if Danfoss DC Drives show an earth fault?
    • T
      Tanya LopezSep 3, 2025
      If your Danfoss DC Drives indicates an earth fault, it means there's current leaking from the output phases to ground, either in the cable between the frequency converter and the motor, or within the motor itself. The solution is to remove power to the frequency converter and repair the earth fault.
  • D
    Dennis HallSep 7, 2025
    What to do for option detection issues in Danfoss DC Drives?
    • S
      swansonmonicaSep 7, 2025
      If your Danfoss DC Drives detects a change in the option layout, enable option layout changes to apply the change.
  • C
    Christopher AllenSep 1, 2025
    What to do if Danfoss DC Drives show External error DI1?
    • S
      Sarah PatelSep 1, 2025
      If your Danfoss DC drive is showing 'External error DI1', it could be due to a safety input connected to DI1 having an illegal signal level, or the sensor might be broken. You can resolve this by checking that the configuration of DI1 (parameter 42-21 Type, sub-index [0]) is set correctly and that the connected sensor is installed according to specification. Additionally, you can extend the discrepancy time for DI1 using the VLT® Motion Control Tool MCT 10 Safe Plug-in.
  • J
    Joseph KramerAug 28, 2025
    How to troubleshoot a motor not reaching maximum speed on Danfoss VLT CANopen MCA 105 DC Drives?
    • B
      Brianna ClarkAug 28, 2025
      If the motor is not reaching its maximum speed using Danfoss DC Drives, program the correct frequency limits. Also, ensure that the reference input signal is scaled correctly by adjusting the settings.
  • M
    Michael DownsSep 9, 2025
    What does '1.8 V supply low' mean on Danfoss VLT CANopen MCA 105?
    • S
      scott93Sep 9, 2025
      If the 1.8 V DC supply is low on your Danfoss DC Drives, it indicates that the 1.8 V DC supply used on the control card is outside of allowable limits. Check for a defective control card.
  • A
    Anthony SmithSep 5, 2025
    What to do for a brake chopper fault in Danfoss VLT CANopen MCA 105 DC Drives?
    • M
      Melvin LopezSep 5, 2025
      If your Danfoss DC Drives reports a brake chopper fault, and a short circuit occurs, the brake function is disabled. Remove power to the frequency converter and remove the brake resistor.
  • W
    Wesley RussellAug 27, 2025
    Why Danfoss DC Drives power on with red light?
    • H
      holly16Aug 27, 2025
      If your Danfoss DC Drives show 'Power On' and the indicator is red, this typically indicates an IP Address Conflict. Resolve the IP conflict.