Parameter 3-36 CAM Master Table
Table 218: Parameter 3-36 CAM Master Table
3-36 CAM Master Table
Default value: 0
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32, Array [20]
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Master position which together with the corresponding element of parameter 3-37 CAM Follower Table forms a CAM position point.
Parameter 3-37 CAM Follower Table
Table 219: Parameter 3-37 CAM Follower Table
3-37 CAM Follower Table
Default value: 0
Parameter type: Range, -2147483648 - 2147483647 [AbsolutePositionU-
nit]
Setup: All setups
Conversion index: 0
Data type: Int32, Array [20]
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Follower position which together with the corresponding element of parameter 3-36 CAM Master Table forms a CAM position point.
Parameter 3-38 CAM Curve Table
Table 220: Parameter 3-38 CAM Curve Table
3-38 CAM Curve Table
Default value: [0] None
Parameter type: Option
Setup: All setups
Conversion index: 0
Data type: Uint8, Array [20]
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Option
Name
Description
[0]*
None
[1]
Linear
Connects the CAM table point with a straight line, corresponds to a fixed gear ratio between master and
follower.
[2]
Poly x'order
Connects the CAM table points with an x-order polynomial where x is determined by the number of con-
secutive points of this type.
[3]
Poly 2'order
Connects the CAM table points with a 2
nd
order polynomial.
[4]
Poly 3'order
Connects the CAM table points with a 3
rd
order polynomial.
[5]
Poly 4'order
Connects the CAM table points with a 4
th
order polynomial. At least 2 consecutive CAM table points of
this type are required to use this selection.
AU275636650261en-000101 / 130R0334 | 141Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals