N O T I C E
This option is only available with software version 48.XX.
Positioning is completed and the on-target signal is sent when the actual position is within pa-
rameter 3-05 On Reference Window for the duration of parameter 3-09 On Target Time and the ac-
tual speed does not exceed parameter 3-05 On Reference Window.
N O T I C E
This option is only available with software version 48.XX.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time set in
parameter 4-72 Position Error Timeout.
N O T I C E
This option is only available with software version 48.XX.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07 Maxi-
mum Position.
N O T I C E
This option is only available with software version 48.XX.
The target position is reached in touch probe position mode.
N O T I C E
This option is only available with software version 48.XX.
Touch probe positioning is active. The drive monitors the touch probe sensor input.
N O T I C E
This option is only available with software version 48.XX.
The touch sensor has been detected.
N O T I C E
This option is only available with software version 48.XX.
The virtual master is running on the set reference.
AU275636650261en-000101 / 130R0334204 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302