Parameter 8-53 Start Select
Table 530: Parameter 8-53 Start Select
Default value: [3] Logic OR
Change during operation: True
Select the trigger for the start function.
A digital input triggers the start function.
A serial communication port or the fieldbus triggers the start function.
The fieldbus/serial communication port and a digital input trigger the start function.
The fieldbus/serial communication port or a digital input triggers the start function.
Parameter 8-54 Reversing Select
Table 531: Parameter 8-54 Reversing Select
Default value: Size related
Change during operation: True
Select the trigger for the reversing function.
A digital input triggers the reversing function.
A serial communication port or the fieldbus triggers the reversing function.
The fieldbus/serial communication port and a digital input trigger the reversing function.
The fieldbus/serial communication port or a digital input triggers the reversing function.
Parameter 8-55 Set-up Select
Table 532: Parameter 8-55 Set-up Select
Default value: [3] Logic OR
Change during operation: True
Select the trigger for the setup selection.
A digital input triggers the setup selection.
A serial communication port or the fieldbus triggers the setup selection.
The fieldbus/serial communication port and a digital input trigger the setup selection.
The fieldbus/serial communication port or a digital input triggers the setup selection.