N O T I C E
This option is only available with software version 48.2X and newer.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time set
in parameter 4-72 Position Error Timeout.
N O T I C E
This option is only available with software version 48.2X and newer.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
N O T I C E
This option is only available with software version 48.2X and newer.
Target position is reached in touch probe position mode.
N O T I C E
This option is only available with software version 48.2X and newer.
Touch probe positioning is active. The drive monitors the touch probe sensor input.
Parameter 13-11 Comparator Operator
Table 675: Parameter 13-11 Comparator Operator
13-11 Comparator Operator
Default value: Size related
Parameter type: Option, Array [10]
Change during operation: True
Select the operator to be used in the comparison. This is an array parameter containing comparator operators 0–5.
N O T I C E
If [20] Alarm number or [21] Warning number is selected in parameter 3-10 Comparator Operand, [0] <
cannot be selected in this parameter.
The result of the evaluation is true when the variable selected in
parameter 13-10 Comparator Operand
is smaller than the fixed value in parameter 13-12 Comparator Value. The result is false if the variable
selected in parameter 13-10 Comparator Operand is greater than the fixed value in parameter 13-12
Comparator Value.
The result of the evaluation is true when the variable selected in parameter 13-10 Comparator Operand
is approximately equal to the fixed value in parameter 13-12 Comparator Value.