Option
Name
Description
[224]
Position error
N O T I C E
This option is only available with software version 48.2X and newer.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time set
in parameter 4-72 Position Error Timeout.
[225]
Position limit
N O T I C E
This option is only available with software version 48.2X and newer.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
[226]
Touch on target
N O T I C E
This option is only available with software version 48.2X and newer.
Target position is reached in touch probe position mode.
[227]
Touch activated
N O T I C E
This option is only available with software version 48.2X and newer.
Touch probe positioning is active. The drive monitors the touch probe sensor input.
[249]
Therm. sensor temp.
Parameter 13-11 Comparator Operator
Table 675: Parameter 13-11 Comparator Operator
13-11 Comparator Operator
Default value: Size related
Parameter type: Option, Array [10]
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Select the operator to be used in the comparison. This is an array parameter containing comparator operators 0–5.
Op-
tion
Name
Description
[0]
<
N O T I C E
If [20] Alarm number or [21] Warning number is selected in parameter 3-10 Comparator Operand, [0] <
cannot be selected in this parameter.
The result of the evaluation is true when the variable selected in
parameter 13-10 Comparator Operand
is smaller than the fixed value in parameter 13-12 Comparator Value. The result is false if the variable
selected in parameter 13-10 Comparator Operand is greater than the fixed value in parameter 13-12
Comparator Value.
[1]
≂ (equal)
The result of the evaluation is true when the variable selected in parameter 13-10 Comparator Operand
is approximately equal to the fixed value in parameter 13-12 Comparator Value.
AU275636650261en-000101 / 130R0334 | 387Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals