Parameter 30-90 SSID
Table 1098: Parameter 30-90 SSID
Default value: Size related
Parameter type: Range, 20.0 - 1000.0 Hz
Change during operation: True
Enter the wireless network name (SSID). The default value is: Danfoss_<Serial number of the drive>. The serial number is in parame-
ter 15-51 Frequency Converter Serial Number.
Parameter 30-91 Channel
Table 1099: Parameter 30-91 Channel
Parameter type: Range, 1 - 11
Change during operation: True
Enter the wireless channel number. The default channel number is 5. Change the channel number, if there is an interference from
other wireless networks. Recommended channels: USA territory: 1, 6, 11. Europe: 1, 7, 13.
Parameter 30-92 Password
Table 1100: Parameter 30-92 Password
Default value: Size related
Parameter type: Range, 8 - 48
Change during operation: True
Enter the wireless network password. Password length: 8–48 characters.
Parameter 30-97 Wifi Timeout Action
Table 1101: Parameter 30-97 Wifi Timeout Action
30-97 Wifi Timeout Action
Default value: [0] Do nothing
Change during operation: True
Select which action to execute if a local reference (hand-on mode) or a remote reference (auto-on mode) is set via the wireless
connection and the connection is lost.
The drive does not do any extra actions.
The drive stops the motor (if the motor was started via a wireless connection).
Parameter 30-98 Remote SSID
Table 1102: Parameter 30-98 Remote SSID
Default value: Size related
Parameter type: Range, 1 - 32
Change during operation: True
AU275636650261en-000101 / 130R0334 | 585Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide