Parameter 40-52 Speed PID Anti Windup Gain
Table 1365: Parameter 40-52 Speed PID Anti Windup Gain
40-52 Speed PID Anti Windup Gain
Default value: Size related
Parameter type: Range, 0 - 500%
Setup: All setups
Conversion index: 0
Data type: Int16
Change during operation: True
This Flux parameter is active in the drive when the following parameters are set to 1 of the values listed here:
Parameter 1-00 Configuration Mode
[0] Speed open loop or
[1] Speed closed loop or
[4] Torque open loop
Parameter 1-01 Motor Control Principle
[2] Flux sensorless or
[3] Flux w/motor feedback
Parameter 1-10 Motor Construction
[0] Asynchron or
[1] PM, non-salient SPM or
[2] PM, salient IPM
Parameter 40-53 Current PID Anti Windup Gain
Table 1366: Parameter 40-53 Current PID Anti Windup Gain
40-53 Current PID Anti Windup Gain
Default value: Size related
Parameter type: Range, 0 - 500%
Setup: All setups
Conversion index: 0
Data type: Int16
Change during operation: True
This Flux parameter is active in the drive when the following parameters are set to 1 of the values listed here:
Parameter 1-00 Configuration Mode
[0] Speed open loop or
[1] Speed closed loop or
[4] Torque open loop
Parameter 1-01 Motor Control Principle
[2] Flux sensorless or
[3] Flux w/motor feedback
Parameter 1-10 Motor Construction
[0] Asynchron or
[1] PM, non-salient SPM or
[2] PM, salient IPM
Parameter 40-54 Flux /w Feedback Dynamic Mode
Table 1367: Parameter 40-54 Flux /w Feedback Dynamic Mode
40-54 Flux /w Feedback Dynamic Mode
Default value: [0] Off
Parameter type: Option, array [2]
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
AU275636650261en-000101 / 130R0334666 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals