FC 300 Design Guide
How to Read this Design Guide
Automatic Motor Adaptation, AMA:
AMA algorithm determines the electrical parameters for the connected m otor at standstill.
B
rake Resistor:
The brake resistor is a module capable of absorbing the brake power generated in regenerative
braking. This regenerative braking energy increases the intermediate circuit voltage and a brake
chopper ensur es that the power is transmitted to the brake resistor.
C
T Characteris tics:
Constant torque characteristics used for all applications such as conveyor belts and cranes.
D
igital inputs:
The digital inputs can be used for controlling various functions of the ad justable frequency drive.
D
igital Outputs:
The d rive features two solid state outputs that can supply a 24 V DC (max. 40 mA) signal.
Relay Outputs
The drive features two programmable Relay Outputs.
H
iperface
®
Hiperface
®
is a registere d trademark by Stegmann.
I
nitializing:
If initializing is carried out (par. 14-22), the adjustable frequency drive returns to the default setting.
L
CP:
The Local Control Panel (LCP) provides a complete interface for control and programming of the FC
300 Series. The control panel is d etacha ble and can be installed up to 9.8 ft (
3meters)fromthe
adjustable frequency drive, i.e. in a front panel by means of the installation kit option.
l
sb:
Least significant bit.
M
CM:
Short for Mille Circular Mil, an Am erican measuring unit for cable c
ross-section.
1MCM≡ 0.00079 in.
2
(0.5067 mm
2
).
m
sb
Most significant bit.
O
n-line/Off-line Parameters:
Changes to on-line parameters are activated immediately a
fter the data value is changed. Changes
to off-line parameters are not activated until you enter [ OK] on the LCP.
P
rocess PID:
The PI D regula tor mainta ins the desired speed, pressure, temperature, etc. by adjusting
the output frequency to match the varying load.
P
ulse Input/Incremental Encoder:
An external, digital pulse transmitter used for fe eding back information on motor speed. The encoder
is used in applications where grea t accuracy in speed control is required.
R
CD:
Residual Current Device.
11
MG.33.B3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals