28
Technical information
Data
Technical data:
Model
-
CDP 35
CDP 45
CDP 65
Working area, humidity
%RF
40-100
40-100
40-100
Working area, temperature
°C
10-36
10-36
10-36
Air volume at max. external
pressure
m
3
/h
250
500
750
Power supply
V/Hz
1 × 230/50
1 × 230/50
1 × 230/50
Max. power consumption
kW
0.72
1.05
1.65
Max. ampere consumption
A
2.8
4.3
7.2
Refrigerant
-
R407C
R407C
R407C
Quantity of refrigerant
kg
0.6
0.95
1.6
GWP (Global Warning Poten-
tial)
-
1653
Noise level* (1 m away from
unit)
dB(A)
44
46
48
Weight
kg
57
68
95
Dimensions, H × L × W
mm
680 × 890 ×
290
680 × 1200 ×
290
680 × 1735 ×
290