EasyManua.ls Logo

Darex XPS-16+ - Splitting, Grind Time, and Chuck Problems

Darex XPS-16+
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Length of time drill required to grind becomes excessive:
• Material take off too excessive
• Grinding wheel needs to be cleaned
• Grinding wheel needs to be replaced
• Grind material selection has been changed from HSS to CARBIDE
Unable to secure drill in or release drill from chuck:
• Solenoid not locking up
• Chuck spindle insert needs cleaned
• Drill is carbide and needs to be centered while closing the chuck
• Drill diameter too small to be clamped
• Drill has multiple diameters that are interfering with jaws
• Drill has a taper in the shank or on the body of the drill
During initialization chuck tries to rotate unsuccessfully while making a ratcheting/
buzzing noise:
• Solenoid has malfunctioned and chuck locking pin will not retract
• Solenoid fuse blown
• Drive pulley loose
• Belt condition
Unexplained motion
• Machine temperature is too cold/hot - do not operate until machine temperature reaches 7°C
(45°F) but not more than 32° C (90° F)
• Software issues – restore settings from permanent memory
Troubleshooting Vacuum:
• Excessive grinding dust visible.
• Vacuum not operational.
• Dirty lter.
• Hoses split.
• Hoses not connected.
• Filter top box or bottom not seated properly.
Vacuum not operational:
• Blown fuse
• Not plugged into sharpener
• Bad control circuit on power supply
• Vacuum motor burned out