LOCATION 424-427: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 10
Locations 424-427 are used to control the communicator code for zone 10. Zone 10 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “10" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 10 is defaulted to report, a "5555 5551 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:0:5" with telephone number 1 and the event log enabled.
LOCATION 428-431: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 11
Locations 428-431 are used to control the communicator code for zone 11. Zone 11 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “11" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 11 is defaulted to report, a "1555 5555 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:1:5" with telephone number 1 and the event log enabled.
LOCATION 432-435: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 12
Locations 432-435 are used to control the communicator code for zone 12. Zone 12 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “12" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 12 is defaulted to report, a "5155 5555 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:2:5" with telephone number 1 and the event log enabled.
LOCATION 436-439: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 13
Locations 436-439 are used to control the communicator code for zone 13. Zone 13 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “13" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 13 is defaulted to report, a "5515 5555 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:3:5" with telephone number 1 and the event log enabled.
LOCATION 440-443: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 14
Locations 440-443 are used to control the communicator code for zone 14. Zone 14 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “14" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 14 is defaulted to report, a "5551 5555 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:4:5" with telephone number 1 and the event log enabled.
LOCATION 444-447: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 15
Locations 444-447 are used to control the communicator code for zone 15. Zone 15 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “15" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 15 is defaulted to report, a "5555 1555 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:5:5" with telephone number 1 and the event log enabled.
LOCATION 448-451: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 16
Locations 448-451 are used to control the communicator code for zone 16. Zone 16 is automatically enabled and When
contact I.D is selected, the default report is an event "130 - Burglary" with point “16" when in alarm. Refer to appendix 1 if
a different event type is required. When using Ademco High Speed, Zone 16 is defaulted to report, a "5555 5155 7" when
in alarm. Ademco High Speed is a predefined format and only the Channel number can be programmed in Data 3. The
defaults are “3:1:6:5" with telephone number 1 and the event log enabled. Note: The Autotest communicator code must
be enabled in locations 308-311 for Autotest to report.