Enter Configuration Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$
-
81
ISBT 128
ÌAI31CÎ
Enabling ISBT 128 automatically disables Puzzle Solver™.
CODE LENGTH (optional)
The code length selection is valid for the entire Code 128 family.
Read the code + 4 numbers for the code length where:
First 2 digits = minimum code length
Second 2 digits = maximum code length
set code length
ÌAILJÎ
The maximum code length is 99 characters. The minimum code length must always be less
than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only.
The length is calculated on the output string.
C
ODE
93
disables the code
ÌAK0aÎ
Code 93
ÌAK1dÎ
control without transmission
of check digit