MATRIX N FAMILY HOST MODE PROGRAMMING
22
- 5 -
Get Matrix 410N Device Information:
The programming string is:
GET_INFO<CR><LF>
Device Response:
ACKModel name: M410N:700-010
MAC address: 00:07:BE:01:2B:56
Serial number: C14P00584
Device name: Matrix
Application version: 1.4.0.1073
Current Job: Phase Mode
- 6 -
Transfer all pending images from all devices in the cluster:
The programming string is:
SEND_IMAGES *<CR><LF>
- 7 -
Transfer images from slave 2 starting from pack/phase 123:
The programming string is:
SEND_IMAGES 2 123<CR><LF>
- 8 -
Transfer images from Master for packs/phases 10 to 12:
The programming string is:
SEND_IMAGES 0 10 12<CR><LF>