3 MECHANICAL MOUNTING
The emitting (TX) and receiving (RX) units must be installed with the relevant sensitive surfaces facing each other.
The connectors must be positioned on the same side and the distance must be included within the operating range
of the model used (see cfr.TECHNICAL DATA page 43).
The two units shall be positioned so as to be aligned and parallel as much as possible.
The next step is the fine alignment, as shown in chapter ALIGNMENT PROCEDURE page 33.
Two types of brackets can be used to fix the two units:
Angled fixing brackets are supplied with all models (Fig 19 - page 27).
Adjustable supports for correcting unit inclination on the axes are available on request (see cfr.ACCESSORIES
page 48).
Rotating brackets (Fig 20 - page 27), available upon request, can be used as an alternative or together with
angled brackets.
For fixing with rotating bracket, refer to Fig 21 - page 28.