6 FUNCTIONS SETTING
6.1 RESET MODE
The interruption of a beam due to an opaque object causes the opening of OSSD outputs and the stop of the safety
light curtain SAFE (BREAK) condition.
The ESPE will automatically restart its standard operation NORMAL OP. ) condition) as soon as the object is
removed.
Carefully assess risk conditions and reset modes.
In applications protecting access to dangerous areas, the automatic reset mode is
potentially unsafe if it allows the operator to pass completely beyond the sensitive area
(see Fig 11 - page 19).
In this case, the reset, using for example the manual reset of the SE-SR2 relay,
(cfr.Notes on connections page 29 might be necessary.