8.2 DIAGNOSTIC MESSAGES
The operator is able to check the main causes of the system stop and failure, using the same LEDs used for
visualising the functions.
For Receiver:
Light curtain being tested, the OSSD status
shall be OFF
Emission
(OSSD ON) (green ON)
Light curtain working and in standard
operating conditions
Interruption (OSSD OFF)
(red ON)
Light curtain working and in safety block
conditions.
OSSD error (yellow and
red BLINKING)
Check OSSD connections; make sure that
they are not in contact with one another or
with the supply cables, then Reset. If the
failure continues contact DATALOGIC.
Internal error (red ON,
yellow BLINKING)
Switch OFF and switch ON the supply circuit;
if the failure continues contact DATALOGIC.
Optical error (red ON,
yellow BLINKING)
Reset. If the failure continues contact
DATALOGIC.
No power supply (LEDs
OFF)
Check connections and input voltage correct
value. If the failure continues contact
DATALOGIC.
Light curtain being tested, the OSSD status
must be OFF
Emission
(green ON yellow ON)
Light curtain working in normal operating
conditions
Internal error (green ON
yellow BLINKING)
Switch OFF and switch ON the power supply
circuit. If the failure continues contact
DATALOGIC.
Optic error (green ON
yellow BLINKING)
Switch OFF and switch ON the power supply
circuit. If the failure continues contact
DATALOGIC.
No power supply
(LEDs OFF)
Check connections and input voltage value. If
the failure continues contact DATALOGIC.