11 TECHNICAL DATA
SAFETY CATEGORY:
Type 2 (rif. EN 61496-1: 2013)
SIL 1 (rif. EN 61508)
SIL CL 1 (rif.EN 62061:2005/A2: 2015)
PL c, Cat. 2 (rif. EN ISO 13849-1: 2015)
PFHd [1/h] = 1,04E -08
MTTFd [years] = 273
ELECTRICAL DATA
Power supply (Vdd):
24 VDC ± 20%
Consumption (TX):
2 W max
Consumption (RX):
3.5 W max (without load)
Outputs:
2 PNP
Short-circuit protection:
1.4 A max
Output current:
0.5 A max su ciascuna uscita
Output voltage status ON:
Vdd 1 V min
Output voltage status OFF:
0.2 V max
Capacitive load:
2.2 uF @ 24VDC max
Response times:
see chapter
AVAILABLE MODELS AND RESPONSE TIMES page 44
Controlled height:
150..1800 mm
Auxiliary functions:
Reset / Test
Electrical protection:
Classe I / Classe III (see cfr.ELECTRICAL CONNECTIONS page
29)
Connections:
for receiver:
M12 5-pole
for emitter:
M12 4-pole
Cables length (for power supply):
50 m. max
OPTICAL DATA
Emitting light ):
Infrared, LED (950 nm)
Resolution:
30 - 50 - 90 mm
Operating distance:
0.219 m
Ambient light rejection:
EN 61496-2: 2013
MECHANICAL AND ENVIRONMENTAL DATA
Operating temperature:
-10…+ 55 °C
Storage temperature:
- 25+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (no condensation)
Mechanical protection:
IP 65 EN 60529
Vibrations:
Width 0.35 mm, Frequency 10 55 Hz
20 sweep per axis, 1octave/min EN 60068-2-6
Shock resistance:
16 ms (10 G) 1,000 shocks per axis EN 60068-2-29
Housing material:
Painted aluminium (yellow RAL 1003)
Front side material:
PMMA
Cover material:
PC LEXAN
Weight:
1.35 kg per linear meter for single unit