I-Class
Diag
nostics
(conti
nued)
Menu Item Details
SENSOR READINGS Displays A-D sensor values (0 – 255), where:
THR TRAN RIBM 24V
127 159 093 175
PS HD RANK
000 254 000
Are the sensor readings, where:
THR = Printhead thermistor sensor;
TRAN = Media sensor when set to Gap or Continuous, or
REFL when to Reflective;
RIBM = Ribbon sensor;
24V = 24 VDC sensor;
PS = Present sensor;
HD = Printhead position sensor; and,
RANK = Printhead ranking resistor.
Note: Readings provided here are examples only.
RIBBON SENSOR LIMITS
Displays the values from the ribbon sensor (when
equipped with the thermal transfer option), where:
RIBBON ADC LOW HIGH
070 104
Are the sensor readings (actual values will vary).
4.2.8 MCL Options
The MCL Op
tions menu contains alternate operating selections:
Menu Item Details
MCL OPTIONS
Allows the optional MCL (Macro Command Language)
tool suite to accept peripheral input data, where:
MCL AT POWER-UP
Allows MCL operation to begin when the printer is
turned ON, where:
DISABLED
No MCL operation.
MCL LINK MODE Starts MCL in Link Mode.
MCL PROGRAM MODE Starts MCL in Program Mode.
START MCL Starts MCL after exiting the menu.
Note: Consult your MCL provider for details regarding operation and support.