V110120E iBoot-G2 Page 14
8. Command Line Interface
The iBoot-G2 Command Line Interface (CLI) provides a text based method for communicating with the
iBoot. The syntax of the CLI uses a basic Set (change a variable) and Get (retrieve a variable). The CLI is
accessed through the Telnet protocol and requires a Telnet client program.
8.1. To access the CLI
Open the Telnet client and connect to the IP address set for the iBoot.
Once the conection is made the User: login prompt is presented.
Enter user or admin and press Enter. The prompt will change to Password:.
Enter the admin or user password and press Enter. The prompt will change to iBoot>. This indicates
successful login. Enter commands as needed. When done, enter the logout command.
8.2. iBoot-G2 CLI Syntax
Command Description Factory Default
Control Commands
These commands are used to monitor and control the outlet.
set outlet <on | off | cycle>
This command controls the outlet.
get outlet
This command returns the current status of the outlet.
Device Commands
These commands are available to the administrator only
get location This command returns the iBoot-G2’s location ID. New Boot
set location <20 char. max> This command is used to set the iBoot-G2’s location ID.
set upgrade enable <yes | no> Enables or disables the ability to upload new firmware to the
iBoot-G2.
get upgrade enable This command displays the upload enable status.
logout Terminates the session
reboot This command reboots the iBoot-G2.