20
INTR ODUCT ION
UPS
Input Data
Nominal input voltage DC24V
Input voltage range DC22V~DC26V
Buffer time +Ua+U'HSHQGLQJRQ326V\VWHPDQGFRQ¿JXUDWLRQ
Output Data in Normal Operation
Nominal output voltage DC 21.09V ~ 23.31V
Output current 2.7A
Current limit 9A
Charging
Charge characteristic
curve
Liner mode
End-of-charge voltage DC12.6V
Charge current DC1.35A (C.C. Mode under DC 12.6V)
Ambient temperature
Operation/storage
0°C to +40°C / 20°C to +70°C
Humidity At +25°C 5%~ 95%, no condensation
Other
MTBF (Bellcore mode /
Not including Battery Set)
A target calculated MTBF of the power supply is greater than
200,000 hours under the following condition: 24Vdc input, Full
rated load, 25°C ambient