1 Setting up the machine

1.1 Transport

Checking transport route for width, height, and load-bearing capacity is crucial for safe machine delivery.

1.2 Setup site

Ensuring the floor is strong, rigid, and smooth, and maintaining clearance around the machine is vital for installation.

1.3 Room climate

Maintaining temperature between 18-30°C and humidity below 65% is essential for optimal machine performance.

1.4 Screen

Do not cover the screen during operation to prevent excessive heat development and keep ventilation slots free.

2 Connecting the supply media

2.1 Voltage supply

Ensure power supply meets EN 60204 standards and use a separate circuit with an RCD (Type B) for safety.

2.2 Internet connection

An Internet connection is necessary for remote maintenance, enabling DATRON support and analysis.

2.3 Network integration

Integrate the machine into your network at your own risk, consulting an IT specialist if questions arise.

2.4 Notes regarding the control computer

Use only approved control components and do not install unapproved applications or virus scanners.

2.5 Compressed air supply

Compressed air must be dry, clean, and oil-free, meeting specific purity classes for spindle longevity.

2.6 Cooling lubricant

Select appropriate cooling lubricant based on application; ethanol is not permitted for sparking metals or chip suction.

2.7 Chip suction

Only use suction systems permitted for the material being machined.

3 Technical data

3.1 Dimensions and weight

Provides detailed physical dimensions and weight specifications for the DATRON neo CNC base system.

4 Safety regulations for operating the machine

4.1 Dry machining

In dry machining, dusts harmful to health can be released; use a suitable vacuum cleaner and observe SDS.

4.2 Processing with minimum-quantity cooling lubrication system

Use only DATRON-recommended lubricants; ensure ventilation and label canisters. Suctioning is prohibited with cooling lubricants.

4.3 Use of ethanol as cooling lubricant

Ethanol is flammable and hazardous with sparks; use sparingly and avoid chip suctioning with ethanol.

4.4 Safety instructions for cleaning

When cleaning, wear protective gear for dusts and coolants. Empty chip tray regularly and use an ignition-free vacuum cleaner.

5 Vacuum cleaner (optional)

6 Checklist

Summary

1 Setting up the machine

1.1 Transport

Checking transport route for width, height, and load-bearing capacity is crucial for safe machine delivery.

1.2 Setup site

Ensuring the floor is strong, rigid, and smooth, and maintaining clearance around the machine is vital for installation.

1.3 Room climate

Maintaining temperature between 18-30°C and humidity below 65% is essential for optimal machine performance.

1.4 Screen

Do not cover the screen during operation to prevent excessive heat development and keep ventilation slots free.

2 Connecting the supply media

2.1 Voltage supply

Ensure power supply meets EN 60204 standards and use a separate circuit with an RCD (Type B) for safety.

2.2 Internet connection

An Internet connection is necessary for remote maintenance, enabling DATRON support and analysis.

2.3 Network integration

Integrate the machine into your network at your own risk, consulting an IT specialist if questions arise.

2.4 Notes regarding the control computer

Use only approved control components and do not install unapproved applications or virus scanners.

2.5 Compressed air supply

Compressed air must be dry, clean, and oil-free, meeting specific purity classes for spindle longevity.

2.6 Cooling lubricant

Select appropriate cooling lubricant based on application; ethanol is not permitted for sparking metals or chip suction.

2.7 Chip suction

Only use suction systems permitted for the material being machined.

3 Technical data

3.1 Dimensions and weight

Provides detailed physical dimensions and weight specifications for the DATRON neo CNC base system.

4 Safety regulations for operating the machine

4.1 Dry machining

In dry machining, dusts harmful to health can be released; use a suitable vacuum cleaner and observe SDS.

4.2 Processing with minimum-quantity cooling lubrication system

Use only DATRON-recommended lubricants; ensure ventilation and label canisters. Suctioning is prohibited with cooling lubricants.

4.3 Use of ethanol as cooling lubricant

Ethanol is flammable and hazardous with sparks; use sparingly and avoid chip suctioning with ethanol.

4.4 Safety instructions for cleaning

When cleaning, wear protective gear for dusts and coolants. Empty chip tray regularly and use an ignition-free vacuum cleaner.