8
PLEASE NOTE: All Microlene UV disinfection systems are intended for indoor use
only as they should not be exposed to the elements. The controller will require a
ground fault circuit inter-rupter (GFCI or GFI) outlet and should be mounted beside or
above the reactor.
Orientation
This system has the ambidextrous capability of being able to have the main water
inlet enter from either the left hand side or right hand side of the unit. The units
comes pre plumbed from the factory for a left hand water inlet. To change to a right
hand water inlet follow these simple steps (See Figure 2):
Step 1: Removetheblueltersumphousings(eitheroneortwohousingsdepending
onthemodelpurchased)fromthelterheadandsetaside.
Step 2: Removethelterheadscrewsfromthetopmountingplate(4screwsfora
singleltermodeland8screwsforadoubleltermodel).
Step 3: Carefullylowerthelterhead(orheads)fromtherackassemblyandrotate
180 de-grees. Reassemble onto the rack assembly and take note of the
arrowslocatedonthetopofthelterheadsindicatingwaterow(whichnow
shouldbeindicatingaowdirectionofright-to-left).
Figure 2. System Orientation (water inlet)
Step 4: Remove the stainless steel UV reactor from the two plastic clamps located on
the top of the rack. Carefully remove the top straps securing the reactor with
the aid of a standard (slot) screwdriver). Rotate the reactor 180 degrees (with
the inlet now facing to the left and the lamp connections located towards the
right)andplacebackintothecellclampsandreafxthetwotopstraps.
Ineithertheleftorrightcongurations,tofacilitatelampremoval,ensure
there is enough space at the lamp connector end to safely remove the UV
lamp and/or quartz sleeve (See Figure 3).