EasyManuals Logo

Davis Instruments Vantage Pro2 Console Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Selecting Units of Measure
22
To change units:
1. Select the weather variable.
See “Selecting Weather Variables” on page 21.
2. Press and release 2ND then press UNITS.
The selected variable’s units will change. Repeat
steps 1 and 2 until the desired units appear.
For example, to change the Barometric pressure units, first select Baro-
metric pressure by pressing BAR. Next, press and release 2ND, then
press UNITS. Repeating these steps cycles through the units available
for Barometric pressure: millibars, millimeters, inches, and hectoPas-
cals.
Wind Speed and Direction
1. Press WIND to select wind speed.
2. Wind speed may be displayed in miles per hour (m.p.h.),
kilometers per hour (km/h), meters per second (m/s), and
knots (knots). The 10 minute average wind speed will be displayed in
the ticker.
A solid arrow within the compass rose indicates the cur-
rent wind direction. Arrow caps indicate up to six differ-
ent 10-minute dominant wind directions to provide a
history of the dominant wind directions for the past
hour.
3. Press WIND a second time to display the wind direction in degrees
instead of the wind speed.
Each additional WIND key press toggles the display between wind
speed and wind direction in degrees.
Outside and Inside Temperature
1. Press TEMP to select outside temperature.
Temperature may be displayed in degrees Fahrenheit (ºF)
or Centigrade (ºC).Temperatures can also be displayed in
degrees or in tenths of a degree.
2. Press TEMP again to select inside temperature.
Each consecutive press of TEMP displays temperature readings for any
optional temperature, temperature/humidity, soil temperature, soil mois-
ture stations also connected to your console. The order the optional sen-
2
ND
GRAPH
UNITS
BAROMETER
mb
BAROMETER
BAROMETER
mm
in
Displaying Units:
Barometric Pressure Units: millibars (mb), millimeters (mm) and inches (in)
WIND
TEMP
07395.234 Manual VP2 console Book.book Page 22 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries