Weather Data Specifications
51
Weather Data Specifications
Note: These specifications include optional sensors that may not be installed in your Vantage Pro2
Station.
Weather Data Specifications
Variable Required Sensors Resolution Range
Nominal Accuracy
(+/-)
Barometric
Pressure
*
Included in Console
0.01” Hg; 0.1 mm;
0.1 hPa; 0.1 mb
26” to 32” Hg; 660 to
810 mm; 880 to
1080 hPa; 880 to
1080 mb
**
0.03” Hg; 0.8 mm
Hg; 1.0 hPa; 1.0 mb
Barometric Trend
(3 hour)
Change Rates
Rapidly: .06” H;
1.5 mm Hg; 2 hPa;
2mb
Slowly: .02” H;
0.5 mm Hg;
0.7hPa; 0.7mb
5 Arrow Positions:
Rising Rapidly
Rising Slowly
Steady
Falling Slowly
Falling Rapidly
Evapotranspiration
(ET)
ISS or Temp/Hum
Station & Solar
Radiation sensor
0.01”; 0.25 mm
Daily to 99.99”;
999.9 mm
Monthly & Yearly to
199.99”; 1999.9mm
greater of 5% or
0.01”; 0.25 mm
Inside Humidity Included in Console 1% 10 to 90% 5% RH
Outside Humidity
ISS or Temp/Hum
Station
1% 0 to 100%
3% RH; 4% above
90%
Extra Humidity
ISS or Temp/Hum
Station
1% 0 to 100%
3% RH; 4% above
90%
Dew Point (overall)
ISS or Temp/Hum
Station
1°F; 1°C
-105° to +130°F;
-76° to +54°C
3°F; 1.5°C
Leaf Wetness Leaf & Soil Station 1 0 to 15 0.5
Soil Moisture
Leaf & Soil Station
or Soil Moisture
Station
1 cb 0 to 200 cb
Daily & Storm
Rainfall
Rain Collector
0.01”; 0.25mm to 99.99”; 999.9 mm
greater of 4% or 1
tip,
Monthly & Yearly
Rainfall
0.01”; 0.25mm
(1mm at totals over
2000 mm)
to 199.99”; 19,999
mm
greater of 4% or 1 tip
Rain Rate 0.01”; 0.25 mm
to 100”/hr; 1999.9
mm/hr
greater of 5% or
0.04”/hr; 1 mm/hr
*
Barometric pressure readings are standardized to sea level. Elevation Range: -1500’ to +12,500’; -460 to + 3810
m. Note: The console screen limits display of lower elevation to -999’ when using feet as elevation unit.
**
This is the reduced value after standardizing to sea level.
07395.234 Manual VP2 console Book.book Page 51 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries